Items |
/Asset/a1351.jpg 91-5520R Model 5520, 2.9 Inch (in) Height Digital Controller |
/Asset/a1351.jpg 91-5580R Model 5580, 6.20 Inch (in) Height Digital Controller |
/Asset/a1351.jpg 91-5571 Handheld Terminal |
|||
Description |
N/A
Digital Controller, supports up to 20 ionizers Simco-Ion's Digital Controller Models 5520 control and monitor parameters and ionizer performance for the Digital Ceiling Emitter Model 5511 and the Digital AeroBar® Ionizer Model 5585. Both controllers allow individual or system wide ionizer control. |
N/A
Digital Controller, supports up to 80 ionizers Simco-Ion's Digital Controller Models 5580 control and monitor parameters and ionizer performance for the Digital Ceiling Emitter Model 5511 and the Digital AeroBar® Ionizer Model 5585. Both controllers allow individual or system wide ionizer control. |
N/A Simco-Ion's Digital Controller Models 5520 and 5580 control and monitor parameters and ionizer performance for the Digital Ceiling Emitter Model 5511 and the Digital AeroBar® Ionizer Model 5585. Both controllers allow individual or system wide ionizer control. | |||
Brands | N/A Simco-Ion™ | N/A Simco-Ion™ | N/A | |||
Power | N/A 4 W plus 1 W per ionizer | N/A 4 W plus 1 W per ionizer | N/A | |||
Alternating Current (AC) Input Voltage1 | N/A 100 V115 V250 V | N/A 100 V115 V250 V | N/A | |||
Voltage Tolerance (±) | N/A 10 % | N/A 10 % | N/A | |||
Frequency | N/A 50 Hz60 Hz | N/A 50 Hz60 Hz | N/A | |||
Alternating Current (AC) Output Voltage | N/A 24 V | N/A 24 V | N/A | |||
Output Signal | N/A RS-485 link to emitters AeroBars® | N/A RS-485 link to emitters AeroBars® | N/A | |||
Capacity | N/A 20 Model 5511 Ceiling Emitters Model 5585 AeroBars® | N/A Model 5585 AeroBars® 80 Model 5511 Ceiling Emitters | N/A | |||
Interface | N/A On-board LCD screen, six keys for some access to operating variables Handheld Terminal Model 5571 connects for full access Second multi-drop RS-485 channel for communication to host PC or FMS system Relay or 4-20 mA outputs for remote alarm indication | N/A On-board LCD screen, six keys for some access to operating variables Handheld Terminal Model 5571 connects for full access Second multi-drop RS-485 channel for communication to host PC or FMS system Relay or 4-20 mA outputs for remote alarm indication | N/A | |||
Indicators | N/A Audible beep indicates alarm and/or other conditions Green LED for power on Red LED for alarm | N/A Audible beep indicates alarm and/or other conditions Green LED for power on Red LED for alarm | N/A | |||
Height | N/A 2.96 in7.52 cm | N/A 6.20 in15.75 cm | N/A | |||
Width | N/A 2.76 in7.01 cm | N/A 4.37 in11.10 cm | N/A | |||
Length | N/A 12.42 in31.55 cm | N/A 13.2 in33.53 cm | N/A | |||
Weight | N/A 3.5 lb1.59 kg | N/A 7 lb3.18 kg | N/A | |||
Industry Standards/Certifications | N/A European Conformity (CE) Restriction of Hazardous Substances Directive (RoHS) Compliant SEMI F47 Underwriters Laboratories (cULus) | N/A European Conformity (CE) Restriction of Hazardous Substances Directive (RoHS) Compliant SEMI F47 Underwriters Laboratories (cULus) | N/A | |||
Cable Length | N/A | |||||
Type | N/A | |||||
Color | N/A | |||||
Wire Size | N/A | |||||
Number of Conductors | N/A | |||||
Additional Information |
N/A
The smaller Model 5520, which accommodates up to 20 emitters, makes integration inside process tools or small room configurations easy and convenient. The ceiling emitters and AeroBar®'s can be integrated on a controller for a customized solution. Use the controller's on-board LCD screen and push buttons or the Model 5571 handheld remote for operational functions that include assigning individual controller addresses, setting ionizer parameters and synchronization for optimized ion performance. Both models of the Digital Controller poll emitter status to offer system feedback of ionizer performance and alarm status, which can be output to FMS monitoring systems. |
N/A
The larger Model 5580 handles large capacity systems, supporting up to 80 ionizers for full room and tool ionization coverage. The ceiling emitters and AeroBar®'s can be integrated on a controller for a customized solution. Use the controller's on-board LCD screen and push buttons or the Model 5571 handheld remote for operational functions that include assigning individual controller addresses, setting ionizer parameters and synchronization for optimized ion performance. Both models of the Digital Controller poll emitter status to offer system feedback of ionizer performance and alarm status, which can be output to FMS monitoring systems. |
N/A | |||
Features |
N/A
|
N/A
|
N/A | |||
Benefits |
N/A
|
N/A
|
N/A | |||
Handheld Efficiency |
N/A
The Handheld Terminal Model 5571 operates with the 5520 controller, allowing the user to access additional control functions. With 30 keys and a 20-character LCD screen, the Handheld Terminal offers a more detailed look at ionizer performance. Two levels of security access prevent unauthorized system changes. The Handheld Terminal allows the user to change some parameter settings that cannot be accessed using the controller's on-board screen. These include setting alarm threshold percentages for each ionizer with audible alarms, if desired, as indicators that emitter point maintenance is required. The ionizer synchronization feature can be customized to send a start signal to all ionizers on a controller, optimizing effectiveness in adjacent areas. When integrated with a facility monitoring system, setting the polling periods enables the user to control the amount of data collected; setting the retry periods reduces false alarms from communication errors. |
N/A
The Handheld Terminal Model 5571 operates with the 5580 controller, allowing the user to access additional control functions. With 30 keys and a 20-character LCD screen, the Handheld Terminal offers a more detailed look at ionizer performance. Two levels of security access prevent unauthorized system changes. The Handheld Terminal allows the user to change some parameter settings that cannot be accessed using the controller's on-board screen. These include setting alarm threshold percentages for each ionizer with audible alarms, if desired, as indicators that emitter point maintenance is required. The ionizer synchronization feature can be customized to send a start signal to all ionizers on a controller, optimizing effectiveness in adjacent areas. When integrated with a facility monitoring system, setting the polling periods enables the user to control the amount of data collected; setting the retry periods reduces false alarms from communication errors. |
N/A
The Handheld Terminal Model 5571 operates with the 5520 controller, allowing the user to access additional control functions. With 30 keys and a 20-character LCD screen, the Handheld Terminal offers a more detailed look at ionizer performance. Two levels of security access prevent unauthorized system changes. The Handheld Terminal allows the user to change some parameter settings that cannot be accessed using the controller's on-board screen. These include setting alarm threshold percentages for each ionizer with audible alarms, if desired, as indicators that emitter point maintenance is required. The ionizer synchronization feature can be customized to send a start signal to all ionizers on a controller, optimizing effectiveness in adjacent areas. When integrated with a facility monitoring system, setting the polling periods enables the user to control the amount of data collected; setting the retry periods reduces false alarms from communication errors. |
|||
|
Creative thinking may mean simply the realization that there’s no particular virtue in doing things the way they always have been done
~Rudolf Flesch
© 2018 Technical Equipment Sales. All Rights Reserved | Site created by Thomas Marketing Services